Technical data by comparison

Show all x BQ21 x BQ30 x PC200 x Particle counter PC200 incl. calibration certificate x PC220 x PC220 Particle Counter incl. cal. certificate
BQ21
BQ30
PC200
Particle counter PC200 incl. calibration certificate
PC220
PC220 Particle Counter incl. cal. certificate

Technical data Standard scope of delivery Ascertainable measured...

199.99 € incl. VAT Show net price (VAT not included)

You save: 25 %

79.99 € 59.99 € incl. VAT Show net price (VAT not included)

995.00 € incl. VAT Show net price (VAT not included)

1,195.00 € incl. VAT Show net price (VAT not included)

1,195.00 € incl. VAT Show net price (VAT not included)

1,395.00 € incl. VAT Show net price (VAT not included)

Technical data
General information
Article number 3.510.205.095 3.510.205.098 3.510.006.010 3.510.006.011 3.510.006.015 3.510.006.016
Particle concentration
Number of channels 2 2 6 6 6 6
Channel sizes 2,5 µm, 10 µm 2.5 µm, 10 µm 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10.0 µm 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10.0 µm 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10.0 µm 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10.0 µm
Detector type Light-scattering measurement Light scattering Light-scattering measurement Light-scattering measurement Light-scattering measurement Light-scattering measurement
Counting modes Cumulative Concentration, cumulative, differential Concentration, cumulative, differential Concentration, cumulative, differential Concentration, cumulative, differential
Counting efficiency 100% 50 % at 0.3 µm; 100 % for particles > 0.45 µm 50 % at 0.3 µm; 100 % for particles > 0.45 µm 50 % at 0.3 µm, 100 % for particles > 0.45 µm 50 % at 0.3 µm, 100 % for particles > 0.45 µm
Flow rate 2.83 l/m (0.1 ft³/min), controlled by internal pump 2.83 l/m (0.1 ft³/min), controlled by internal pump 2.83 l/min (0.1 ft³/min), controlled by internal pump 2.83 l/min (0.1 ft³/min), controlled by internal pump
Zero count < 1 particle / 5 min < 1 particle / 5 min < 1 particle / 5 min < 1 particle / 5 min
Coincidence loss 5 %, 2 million particles per ft³ (28.3 litres) 5 %, 2 million particles per ft³ (28.3 litres) 5 %, 2 million particles per ft³ (28.3 litres) 5 %, 2 million particles per ft³ (28.3 litres)
Sample inlet Isokinetic probe Isokinetic probe Isokinetic probe Isokinetic probe
Particle mass conversion
Particle mass conversion 2.5 µm, 10 µm 2.5 µm, 10 µm 2.5 µm, 10 µm
Min. measuring range | Particle mass conversion [µg/m³] 0 0 0 0
Max. measuring range | Particle mass conversion [µg/m³] 2,000 2,000 2,000 2,000
Resolution | Particle mass conversion [µg/m³] 1 1 1
HCHO (formaldehyde)
Min. measuring range | Formaldehyde [ppm] 0.01 0.01
Max. measuring range | Formaldehyde [ppm] 5 5
Accuracy ± | Formaldehyde [%] 5 5
Resolution | Formaldehyde [ppm] 1 1
Carbon dioxide (ppm)
Min. measuring range | Carbon monoxide [ppm] 0
Max. measuring range | Carbon dioxide [ppm] 9,999
Accuracy ± | Carbon monoxide [%] 5
Resolution | Carbon monoxide [ppm] 1
Carbon monoxide
Min. measuring range | Carbon monoxide [ppm] 10 10
Max. measuring range | Carbon dioxide [ppm] 1,000 1,000
Accuracy ± | Carbon monoxide [%] 5 5
Resolution [ppm] | Carbon monoxide 1 1
Air temperature
Min. measuring range | Air temperature [°C] 0 -20 0 0 0 0
Max. measuring range | Air temperature [°C] 50 70 50 50 50 50
Min. measuring range | Air temperature [°F] 32 -4 32 32 32 32
Max. measuring range | Air temperature [°F] 122 158 122 122 122 122
Resolution [°C] 0.1 0.1
Resolution [°F] 0.1 0.1
Temperature below 10 °C - Temperature above 40 °C [°C] 1 1 1 1
Temperature below 50 °F - Temperature above 104 °F [°F] 1.8 1.8 1.8 1.8
Accuracy ± 0 °C - 50 °C [°C] 1
Accuracy [°C] 2
Accuracy ± 10 °C - 40 °C [°C] 0.5 0.5 0.5 0.5
Accuracy ± 32 °F - 122 °F [°F] 2
Accuracy ± 50 °F - 104 °F [°F] 0.9 0.9 0.9 0.9
Relative humidity
Min. measuring range | Relative humidity [%] 0 0 0 0 0
Max. measuring range | Relative humidity [%] 100 100 100 100 100
Display resolution [%RH] 0.1 0.1
Min. measuring range | Relative humidity [%RH] 0
Max. measuring range | Relative humidity [%RH] 100
Accuracy 0 % - 20 % [%] 5 5 5 5 5 5
Accuracy 20 % - 80 % [%] 3.5 3.5
Accuracy 80 % - 100 % [%] 5 5 5 5 5 5
Accuracy 40 % - 60 % [%] 3 3 3 3
Accuracy 20 % - 40 % [%] 3.5 3.5 3.5 3.5
Accuracy 60 % - 80 % [%] 3.5 3.5 3.5 3.5
Dew point temperature
Min. measuring range | Dew point temperature [°C] 0 0 0 0
Max. measuring range | Dew point temperature [°C] 50 50 50 50
Min. measuring range | Dew point temperature [°F] 32 32 32 32
Max. measuring range | Dew point temperature [°F] 122 122 122 122
Accuracy ± 10 °C - 40 °C [°C] 1 1 1 1
Accuracy ± 50 °F - 104 °F [°F] 1.8 1.8 1.8 1.8
Wet-bulb temperature
Min. measuring range | Wet-bulb temperature [°C] 0 0 0 0
Max. measuring range | Wet-bulb temperature [°C] 80 80 80 80
Min. measuring range | Wet-bulb temperature [°F] 32 32 32 32
Max. measuring range | Wet-bulb temperature [°F] 176 176 176 176
Accuracy ± | Wet-bulb temperature [°C] 1 1 1 1
Accuracy ± | Wet-bulb temperature [°F] 1.8 1.8 1.8 1.8
Display
TFT colour LCD 2.0"
220 x 176 px
3" TFT LCD display
LCD
Colour
Monochrome
Touch
Memory organisation
Internal flash memory 5,000 measurements Internal flash memory Up to 5,000 data records Up to 5,000 data records Up to 5,000 data records Up to 5,000 data records
Extended data memory (microSD, optional) - (max. 16 GB)
Photo storage format JPEG (640 x 480) JPEG (640 x 480) JPEG (640 x 480) JPEG (640 x 480)
Video storage format 3GP (320 x 240) 3GP (320 x 240) 3GP (320 x 240) 3GP (320 x 240)
Interfaces
Bluetooth
USB
3.5 headphone jack
3.5 mm audio jack (headphones)
Power supply
Internal battery (Li-ion)
Via mains voltage
Battery type 1 x 3.7 V lithium polymer battery Polymer LI-ION battery Polymer LI-ION battery Polymer LI-ION battery Polymer LI-ION battery
Internal (battery)
External (power adapter)
External (USB)
Operating time
Approx. 4 hours of continuous operation
> 30 h
Charging time
Approx. 2 hours with connected AC adapter
Housing design
Plastics
Metal
Ambient conditions
Operation - min. temperature [°C] 0 0 0 0 0 0
Operation - max. temperature [°C] 40 50 50 50 50 50
Operation – max. relative humidity (non-condensing) [%] 80 100 80 80 80 80
Storage - min. temperature [°C] -10 -10 -10 -10 -10
Storage - max. temperature [°C] 50 60 60 60 60
Storage - max. relative humidity [%] 90
Dimensions
Length (packaging excluded) [mm] 188 85 240 240 240
Width (packaging excluded) [mm] 35 75 58 58 58
Height (packaging excluded) [mm] 52 155 75 75 75
Weight
(packaging excluded) [kg] 0.175 0.36 0.435 0.435 0.435 0.435
Standard scope of delivery
Standard scope of delivery
Measuring device
Li-ion battery (integrated)
Wire stand
Mini USB cable
Charger (USB 5 V, 1 A)
Getting started guide
Battery(-ies)
Lithium polymer battery
Operating manual
Charger
Zero filter with connection hose
Mini tripod
Transport case
USB cable
Software
Calibration certificate
Ascertainable measured values and functions
Internal sensors
Particle concentration [n/l]
Dew point temperature [°F]
Sound [dBC]
Sound [dBA]
Microwave radiation [mW/cm²]
Light [lx]
Light [fc]
Carbon monoxide [ppm]
Combustible gases [indicativeviaacousticsignaldependingontheconcentration]
Wet-bulb temperature [°F]
Wet-bulb temperature [°C]
Air temperature [°C]
Dew point temperature [°C]
Particle concentration [n/m³]
Temperature [°F]
Temperature [°C]
CO2
Mass concentration PM2.5/PM10
Relative humidity [%]
Air temperature [°F]
HCHO [ppm]
Functions and features
Simultaneous measurement PM2.5 and PM10
Calibration option
Average value display
Language selection
°C/°F switching
Photo recording
Video recording
Automatic display switch-off - (90 seconds, 2 minutes or 4 minutes)
4-digit measuring value display
Measured value hold function
A/C frequency weighting
Limit value alarm
Light detector
Microphone
Gooseneck probe
Automatic display switch-off
Calibration function
Reversible time weighting
Minimum value display
Bar graph indicator
Integrated foot
Switching function °C/°F
Memory for 5,000 measured values
Bluetooth interface
Automatic switch-off
Time
Battery status indication
¼ inch tripod thread
Automatically alternating indication of all measured climate parameters
Maximum value display
Measurement of temperature, relative humidity, CO2, configurable measuring rate, optional XY-diagram
Automatic Baseline Calibration
Visual alarm function
Acoustic alarm function
Date
Adjustable display brightness
Display illumination
Backlit display

 standard equipment

 optionally available

 not available