Alle einblenden x AC080V x EC060V x IC085LV x IC125LV
AC080V
EC060V
IC085LV
IC125LV

Technical data Equipment, features and... Standard scope of delivery Ascertainable measured...

Preis auf Anfrage

Preis auf Anfrage

Preis auf Anfrage

Preis auf Anfrage

Technical data
General information
Article number 3.110.003.031 3.110.003.004 3.110.003.014 3.110.003.023
Temperature (°C)
Min. measuring range [°C] -20 -20 -20 -20
Max. measuring range [°C] 350 250 600 1,500
Max. accuracy ± 2 °C / ± 2 % ± 2 °C/± 2 % ± 2 °C/± 2 % ± 2 °C/± 2 %
Radiometric image performance
Detector type Focal Plane Array (FPA), uncooled microbolometer Focal Plane Array (FPA), uncooled microbolometer Focal Plane Array (FPA), uncooled microbolometer Focal Plane Array (FPA), uncooled microbolometer
Detector resolution 160 x 120 pixels
Spectral range 8 - 14 µm
Detector resolution 384 x 288 pixels
Spectral range 7.5 - 14 µm
Thermal sensitivity [30°C] 0.08 °C 0.08 °C 0.05 °C 0.05 °C
Image refresh rate 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Geometric resolution 3 mrad 2.2 mrad 1.1 mrad 1.1 mrad
Standard lens 21° x 28° 20° x 15° 24° x 18° 24° x 18°
Minimum focal length 0.5 m 0.10 m 0.10 m 0.10 m
Field of vision (FOV) 21° x 28° 20° x 15° 24° x 18° 24° x 18°
Display
TFT-LCD
Colour
5"
1,080 x 720 px
LCD 3"
LCD 3.5"
Visual image performance (integrated digital camera)
Colour display/resolution 640 x 480 pixels
Focus
Video norm PAL PAL PAL PAL
Standard lens 21° x 28° 20° x 15° 24° x 21° 24° x 21°
Min. focal length 0.3 m 0.5 m 0.5 m 0.5 m
Interfaces
USB 2.0
Bluetooth
WLAN
Mains current 4.2 – 4.8 V DC
Micro USB
Composite video (video out)
Mains connection
BNC
RS-232
Power supply
Via battery (Li-ion)
Via LAN (PoE)
Input voltage [VAC]
Power input heating element [W]
Power input camera [W]
Via mains voltage (5 V, 2.1 A)
12 V, 3 A (cigarette lighter)
Via mains current 9 V DC
Via mains current 4.2 – 4.8 V DC
Operating time
approx. 2 h
approx. 3 h
approx. 2.5 h
Device control
Touch function
Push buttons
Via PC (software)
Via joystick control unit
Memory organisation
Storage medium Flash, 21 GB SD memory card slot MicroSD memory card slot MicroSD memory card slot
Radiometric file format 14-bit IR format 14-bit radiometric IR format 14-bit IR format
Visual file format JPG CCD CCD CCD
File format non-radiometric thermographic video
Voice recording
Ambient conditions
Operation - min. temperature [°C] -20 -15 -15 -15
Operation - max. temperature [°C] 50 50 50 50
Storage - min. temperature [°C] -40 -40 -40 -40
Storage - max. temperature [°C] 70 70 70 70
Min. humidity [%] 10 10 10 10
Max. humidity (non-condensing) [%] 95 95 95 95
Type of protection
IP54 IEC 529
IP66
IP69
MIL-STD-810G
Shock
25G IEC 68-2-29
30G IEC 68-2-29
Vibration
2G IEC 68-2-6
2.5G IEC 68-2-6
Laser
Type Semiconductor AlGalnP diode laser Semiconductor AlGalnP diode laser, 1 mw/ 635 nm red Semiconductor AlGalnP diode laser, 1 mw/ 635 nm red
Classification class 2 class 2 class 2
Wavelength [µm] 635 635 635
Housing design
Plastics
Dimensions
Length (packaging excluded) [mm] 174 175 230 230
Width (packaging excluded) [mm] 102 55 80 80
Height (packaging excluded) [mm] 35 160 195 195
Weight
(packaging excluded) [kg] 0.405 0.5 0.65 0.65
Equipment, features and functions
Standard scope of delivery
Standard scope of delivery
Thermal imaging camera with standard lens
Tripod fixing device
1x Li-ion battery
Video cable
SD memory card (2 GB)
24° x 18° interchangeable lens IC-L/-LV series (standard equipment)
Temperature test certificate
Tripod (1/4" - 20 standard shots)
Lens cap
MicroSD memory card
Operating manual
Transport case
Li-ion battery
Battery charger with charging status indicator
USB cable
Standard software package
Connecting cable for the socket of the wiring system voltage (cigarette lighter)
Bluetooth headset
Docking station
miniSD memory card
SD memory card
SD card reader
Power adapter with mains cable
Ascertainable measured values and functions
Internal sensors
Surface temperature [°C]
Surface temperature [°F]
Functions and features
Image display (pseudo colours, 6 colour palettes)
Freeze function
Up to 9 movable measuring spots (8x manual and 1x automatic temperature tracking)
Area measurement 2 areas
DuoVision Plus, combined display of IR image and contour representation (real image)
Tripod mounting
Manual adjustment of brightness and contrast
Automatic adjustment of temperature range
Alarm function (acoustic) when exceeding/falling below freely configurable temperature values
Automatic measurement correction based on user-defined specifications regarding reflected object temperature
Image display option IR image
Status display
Isotherm measuring function - between upper and lower limit value
Integrated photo lamp
Energy saving mode - user-defined
Image display option real image
Up to 5 movable measuring spots (4x manual and 1x automatic temperature tracking)
Isotherm measuring function
Degree of emission adjustable from 0.1 to 1.0
Automatic measurement correction based on user-defined specifications for ambient temperature, distance, relative humidity
Automatic contrast and brightness setting
Profile analysis
Saving of fully radiometric JPEGs
Data transmission via USB
Integrated digital camera
1x digital zoom
Alarm message via intranet or internet
Distance indication to the object directly in the thermal image (in m or inch)
Up to 4 movable measuring spots (3x manual and 1x automatic temperature tracking)
Colour display in grey and inverted grey
Fixed focus
Camera remote control using binocular control unit via extension cable
Mounting via a 1/4 inch - 20 connection
Noise reduction (3x averaging)
Saving of individual non-radiometric IR images directly on SD card
Temperature comparison function
Binocular control unit with dioptre compensation and eyecup
High definition grey scale OLED
Capable of being integrated in TCP/IP networks
Integrated heating elements for operating temperatures to -35°C
System can be remote-controlled by use of the software
DuoVision function for picture-in-picture display
10x digital zoom (adjustable in 0.1 degrees)
Up to 10 movable measuring spots (9x manual and 1x automatic temperature tracking)
Manual focus
Auto focus
Motor-controlled focus
Image display option different DuoVision options for combined display of IR and real images
Up to 2 movable measuring spots (1x manual and 1x automatic temperature tracking)
Up to 6 movable measuring spots (5x manual and 1x automatic temperature tracking)
Area measurement 1 area
2x digital zoom
Area measurement 5 areas
Voice recording
Tripod
Differential measurement
Integrated, inclinable viewfinder with dioptre compensation (800 x 480 pixels)
Laser pointer
Saving of non-radiometric MPEG-4 IR videos directly on SD card
Monocular control unit with dioptre compensation and eyecup

 Serienausstattung

 optional erhältlich

 nicht verfügbar