Pyrometer TP7
Professional infrared thermometer employing multi-point laser technology
You probably have never seen an infrared thermometer such as the TP7 before, for the practice-optimised German industrial design of this professional pyrometer is a protected design patent and 100 % Trotec.
In addition to the unique exterior looks the TP7 can also score with how it looks like on the inside. A distance factor of 40:1 permits precise measuring results from afar even for small objects.
Owing to the high temperature measuring range from -50 °C to +1,000 °C and the non-contact measurement principle, the robust TP7 is ideally suited for temperature measurements at poorly accessible, hot, movable or dangerous measuring locations.
Precise measurements straight to the multi-point
As should be expected from a professional IR thermometer, the TP7 is equipped with many practice-oriented functions, for instance, it allows the material-specific adjustment of the degree of emission, the indication of the maximum value or non-stop measuring operations.
Special emphasis should be placed on the innovative multi-point laser technology of the TP7. Instead of just pointing to the measuring target by means of a single laser or outlining the size of the measuring spot via double laser, the TP7's multi-point laser combines these two technologies and allows you to capture the measuring object both easily and precisely:
Whilst one targeting laser in the centre indicates the measuring point, further eight lasers show you the boundary points encircling the measuring surface – thus permitting precise measurements in a minimum of time.
Convenient alarm indication via change of display colour
Another time-saving function of the TP7 consists of an alarm-related colour change of the display illumination. You can enter user-defined alarm thresholds for measured minimum and maximum values in the device. Falling below the set limit value, the display will be flashing in blue, exceeding it, in red. In both cases an acoustic alarm signal will be emitted in addition.
Thanks to this intuitive colour indication you can tell from one look whether the measured temperature is within the preset target value range. Consequently, even larger areas can be measured in a timely manner without having to pay attention to each individual measured value.
Optical resolution in a nutshell:
The optical resolution (D:S) defines the ratio of measuring distance and measuring spot diameter. With increasing distance to the measuring object the measuring spot also increases. The infrared thermometer calculates an average temperature from all the temperatures in the measuring spot.
The larger the measuring spot, the less precise is the measured result. And vice versa: the higher the optical resolution of the pyrometer, the smaller the measuring spot and the more precise the measurement.
With the TP7 you'll have a professional infrared thermometer suited for manifold fields of application
All Contact and IR thermometers in direct comparison:
To find the Kontak ve kızılötesi termometre which exactly meets your requirements, please consult the concise overview of all Contact and IR thermometers from Trotec, which we're providing to you here so that you can compare them directly to each other.
Models which you do not wish to include in your comparison can be easily dismissed with only one click.
A few practical benefits:
- Development, design, production: 100 % Trotec
- Optical resolution 40:1
- Non-contact surface temperature measurement from -50 °C to +1,000 °C
- Multi-point laser aiming aid for simultaneous indication of measuring point and measuring spot
- Degree of emission freely adjustable from 0.1 to 1.0
- High/low alarms indicated by a change of display colour and an additional alarm sound
- Backlit display
- Automatic switch-off function
- Practice-optimized German industrial design – protected design patent
Certified safety - factory calibration of measuring devices directly from the manufacturer
As one of the leading full-range suppliers of measuring equipment for building diagnostics and environmental technology, Trotec offers you the opportunity to have all measuring devices calibrated, maintained and repaired from a single source. With a calibrated measuring device, you avoid inaccurate measurement results and can reliably protect yourself against possible recourse claims. So play it safe and use our calibration service for your Trotec measuring devices: In our in-house laboratory, we calibrate according to the factory standard to firmly defined measuring ranges and points. Optionally, the calibration points can also be individually defined within the specified calibration range.
standard equipment
optionally available
not available
Buy
Infrarot-Thermometer / Pyrometer TP7 Multipunkt Laser
You save: 20.00 €
109.99 €
89.99 €
incl. VAT
Show net price (VAT not included)
Technical data
Technical data | ||
---|---|---|
General information | ||
Article number | 3.510.003.012 | |
Optics | ||
Optical resolution (D:S) | 40:1 | |
Smallest measuring spot | 25.4 mm | |
Infrared temperature sensor [°C] | ||
Min. measuring range | Infrared temperature sensor [°C] | -50 | |
Max. measuring range | Infrared temperature sensor [°C] | 1,000 | |
Max. accuracy [°C] | Infrared temperature sensor | ||
Accuracy < -4°C | ||
Accuracy -4°C to 65 °C | ||
Accuracy > 65 °C | ||
Accuracy < 20 °C | ||
Accuracy = 20 °C | ||
Accuracy -50 °C to 20 °C (-58 °F to 68 °F) | ± 2.5 | |
Accuracy 21 °C to 300 °C | ± 1 | |
Accuracy 301 °C to 1,000 °C | ± 1.5 | |
Accuracy 21 °C to 400 °C | ||
Accuracy 401 °C to 800 °C | ||
Accuracy 800 °C to 1,600 °C | ||
Repeatability -50 °C to 20 °C | ± 1.3 | |
Repeatability 21 °C to 1,000 °C | ± 0.8 / ± 0.5 | |
Repeatability 21 °C to 1,200 °C | ||
Repeatability 1,201 °C to 1,600 °C | ||
Accuracy 20 °C to 500 °C (68 °F to 932 °F) | ||
Accuracy 500 °C to 1,000 °C (932 °F to 1,832 °F) | ||
Accuracy 1,000 °C to 1,850 °C (1832 °F to 3,362 °F) | ||
Repeatability 20 °C to 1,000 °C (68 °F to 1,832 °F) | ||
Repeatability 1,000 °C to 1,850 °C (1832 °F to 3,362 °F) | ||
Infrared temperature sensor [°F] | ||
Min. measuring range | Infrared temperature sensor [°F] | -58 | |
Max. measuring range | Infrared temperature sensor [°F] | 1,832 | |
Accuracy ± min. [°F] | 4.5 | |
Accuracy Max. [%] | 1 | |
Integrated temperature probe [°C] | ||
Min. measuring range | Integrated temperature probe [°C] | ||
Max. measuring range | Integrated temperature probe [°C] | ||
Accuracy ± min. [°C] | ||
Accuracy ± Max. [°C] | ||
Integrated temperature probe [°F] | ||
Min. measuring range | Integrated temperature probe [°F] | ||
Max. measuring range | Integrated temperature probe [°F] | ||
Accuracy ± < 23 °F to 150 °F °F [°F] | ||
Accuracy ± > 150 °F [°F] | ||
Dew point temperature [°C] | ||
Min. measuring range | Dew point temperature [°C] | ||
Max. measuring range | Dew point temperature [°C] | ||
Accuracy | ||
Humidity | ||
Min. measuring range | Humidity [%] | ||
Max. measuring range | Humidity [%] | ||
Accuracy [%] | Humidity | ||
Ambient conditions | ||
Operation - min. temperature [°C] | 0 | |
Operation - max. temperature [°C] | 50 | |
Operation – min. relative humidity [% r.F.] | 10 | |
Operation - max. relative humidity (non-condensing) [%] | 90 | |
Storage - min. temperature [°C] | -10 | |
Storage - max. temperature [°C] | 60 | |
Storage - max. relative humidity (non-condensing) [%] | 80 | |
Display | ||
LCD | ||
Monochrome | ||
Interfaces | ||
USB | ||
Plug connection for type K temperature sensor | ||
Memory organisation | ||
Internal flash memory | ||
Device control | ||
Push buttons | ||
Membrane keyboard | ||
Type of protection | ||
IP54 | ||
IP65 | ||
Temperature sensor | ||
Response time | < 150 ms | |
Spectral sensitivity | 8 ~ 14 µm | |
Laser (target display) | ||
Class | class 2 | |
Wavelength [nm] | 630 ~ 670 | |
Power [mW] | 1 | |
Power supply | ||
Internal (battery) | 9V battery | |
External (USB) | ||
Housing design | ||
Plastics | ||
Dimensions | ||
Length (packaging excluded) [mm] | 122 | |
Width (packaging excluded) [mm] | 49 | |
Height (packaging excluded) [mm] | 160 | |
Weight | ||
(packaging excluded) [kg] | 0.224 |
Standard scope of delivery | ||
---|---|---|
Standard scope of delivery | ||
Measuring device | ||
Transport bag | ||
Operating manual | ||
Contact temperature sensor type K | ||
Carrying case | ||
USB cable | ||
Mini tripod |
Ascertainable measured values and functions | ||
---|---|---|
Internal sensors | ||
Material temperature [°C] | ||
Material temperature [°F] | ||
Dew point temperature [°C] | ||
Dew point temperature [°F] | ||
Air temperature [°C] | ||
Air temperature [°F] | ||
Relative humidity [%] | ||
Functions and features | ||
Selectable multi-point laser | ||
Automatic switch-off | ||
Acoustic alarm function | ||
Visual alarm function via LCD illumination in different colours (red/green/blue) | ||
Alarm function with user-defined limit values | ||
Display resolution 0.1°C | ||
Non-stop measuring function | ||
Degree of emission adjustable from 0.1 to 1.0 | ||
Backlit LCD monitor | ||
Maximum value display | ||
Measured value hold function | ||
Switching function for temperature measuring units °C/°F | ||
Acoustic dew point alarm | ||
Bar graph indicator for the quick identification of condensation risks | ||
Battery status indication | ||
Differential value display | ||
Applicable for software-supported recording of measurement series | ||
Degree of emission fixed at 0.95 | ||
Conforms with DIN 10955:2004 | ||
Meets the specifications of the LFGB, §31 (German Food and Feed Code) | ||
HACCP quick indicator LED | ||
Maximum value indication | ||
Minimum value display | ||
Open targeting sights | ||
Tripod thread connection | ||
Timer function | ||
Visual dew point alarm | ||
Additional material temperature measurement using integrated type K insertion sensor | ||
Additional temperature measurement using external type K sensor | ||
Selectable single laser pointer | ||
Material temperature [°C] | ||
Material temperature [°F] |
standard equipment
optionally available
not available