Show all x BL30 x BZ30 x DL200D x DL200H x DL200L x DL200P x DL200X
BL30
BZ30
DL200D
DL200H
DL200L
DL200P
DL200X

Technical data Standard scope of delivery Ascertainable measured...

You save: 32 %

78.35 £ 52.51 £ incl. VAT Show net price (VAT not included)

186.01 £ incl. VAT Show net price (VAT not included)

440.89 £ incl. VAT Show net price (VAT not included)

293.65 £ incl. VAT Show net price (VAT not included)

489.41 £ incl. VAT Show net price (VAT not included)

391.91 £ incl. VAT Show net price (VAT not included)

489.41 £ incl. VAT Show net price (VAT not included)

Technical data
General information
Article number 3.510.205.520 3.510.205.015 3.510.260.040 3.510.260.020 3.510.260.050 3.510.260.030 3.510.260.060
Air temperature [°C]
Measuring principle | Air temperature NTC NTC NTC NTC NTC NTC
Min. measuring range | Air temperature [°C] -40 -5 -20 -20 -20 -20
Max. measuring range | Air temperature [°C] 70 50 50 50 50 50
Accuracy ± | Air temperature [°C] 2 1 0.3 0.3
Display resolution [°C] 0.1 0.1 0.1 0.1 0.1 0.1
Accuracy ± 0 °C - 40 °C [°C] 0.3
Air temperature [°F]
Min. measuring range | Air temperature [°F] -40 23
Max. measuring range | Air temperature [°F] 158 122
Display resolution [°F] 0.1 0.1
Accuracy ± | Air temperature [°F] 1.8 1.8
Relative humidity
Min. measuring range [%RH] 0 0.1
Max. measuring range [%RH] 100 99.9
Accuracy ± [%r.F.] 3.5 2 2 2 2
Display resolution [%RH] 0.1 0.1
Accuracy [%RH] 5
Measuring principle | Relative humidity Capacitive Capacitive Capacitive Capacitive
Min. measuring range [%r.F.] 10 10 10 10
Max. measuring range [%r.F.] 100 100 100 100
Display resolution [%r.f.] 0.5 0.1 0.5 0.5
Accuracy [%r.F.]
Air pressure
measuring principle
Measuring range [hPa] 300 – 1,300 (absolute air pressure)
Accuracy ± [hPa] 0.5
Display resolution [hPa] 0.1
CO2 concentration
Measuring principle NDIR NDIR
Min. measuring range | Carbon dioxide [ppm] 0
Max. measuring range | Carbon dioxide [ppm] 9,999
Accuracy | Carbon dioxide [ppm] 75
Accuracy | Carbon dioxide [%] 5
Accuracy ±75 ppm / ±5 % ± 50 ppm / + 3% of measured value (at 20°C and 1.013 mbar)
Display resolution [ppm] 1 1
Measuring range [ppm] 0 – 5,000
Long-term stability [ppm/a] 20
Thermal element K
Min. measuring range [°C] -200
Max. measuring range | Thermal element K [°C] 1,200
Resolution | Thermal element K [°C] 0.2
Accuracy Between -200 °C ... 0 °C [°C] ±1
Accuracy Between -200 °C ... 0 °C [°C] - Of measured value ±0.5
Accuracy Between 0 °C ... 1.200 °C [°C] ±0
Accuracy Accuracy between 0 °C ... 1.200 °C [°C] - Of measured value ±0.2
Thermal element J
Min. measuring range [°C] -200
Max. measuring range [°C] 1,200
Accuracy -200 °C ... 0 °C [°C] ±1
Accuracy -200 °C ... 0 °C [°C] - Of measured value ±0.5
Accuracy Accuracy between 0 °C ... 1.200 °C [°C] ±1
Accuracy Accuracy between 0 °C ... 1.200 °C [°C] - Of measured value ±0.2
Resolution | Thermal element J [°C] 0.2
Thermal element S
Min. measuring range [°C] -50
Max. measuring range [°C] 1,700
Accuracy Between -50 °C ... 0 °C [°C] ±1
Accuracy Between -50 °C ... 0 °C [°C] - Of measured value 0.5
Accuracy 0 °C ... 1.700 °C [°C] ±1
Accuracy 0 °C ... 1.700 °C [°C] - Of measured value ±0.2
Resolution | Thermal element S [°C] 0.2
PT100
Min measuring range [°C] -200
Max. measuring range [°C] 500
Accuracy [°C] 0.2
Accuracy of the measured value ± | Pt100 [%] 1
Resolution | Pt100 [°C] 0.02
Voltage input
Min. measuring range [V] 0
Max. measuring range [V] 1
Accuracy ± [µV] 200
Accuracy of the measured value - Voltage input ± [%] 1
Resolution < 500
Current measurement
Min. measuring range in two-wire operation [mA] 4
Max. measuring range in two-wire operation [mA] 20
Min. measuring range in three-wire operation [mA] 0
Max. measuring range in three-wire operation [mA] 20
Accuracy ± [µA] 4
Accuracy of the measured value ± | Current measurement [%] 0.1
Resolution [µA] 5
Approx. output load [Ω] 50
Display
LCD
Monochrome
Size [mm] 90 x 64 90 x 64 90 x 64 90 x 64 90 x 64
Memory organisation
Sampling interval as of 1 s > 1 s 10/30s, 1/10/12/15/30 min, 1/3/6/12/24h 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h
Saving interval as of 1 s > 1 s 1/10/12/15/30, 1/3/6/12/24 h 1/10/12/15/30 min, 1/3/6/12/24 h 1/10/12/15/30 min 1/10/12/15/30 min, 1/3/6/12/24 h 1/10/12/15/30 min, 1/3/6/12/24 h
Memory 32,000 Measured values, (16,000 each for temperature and humidity) 50,000 Measured values 16 MB, 3,200,000 measured values 16 MB, 3,200,000 measured values 16 MB, 3,200,000 measured values 16 MB, 3,200,000 measured values 16 MB, 3,200,000 measured values
Data logging Up to 20 measurement channels in parallel Up to 20 measurement channels in parallel Up to 20 measurement channels in parallel Up to 20 measurement channels in parallel Up to 20 measurement channels in parallel
Available measurement channels 32 24 28 Max. 48 Max. 128
Available channel groups 8 6 7 Max. 12 Max. 32
Software TR, EN, EN, ES, FR TR, EN, EN, ES, FR TR, EN, EN, ES, FR TR, EN, EN, ES TR, EN, EN, ES, FR
Interface
USB
LAN
Plug socket
BNC
RS-485
10-pin terminal
Plug socket - 2x
BNC - 2x
Device control
Push buttons
Housing design
Plastics
Power supply
Internal (battery) 1 x 3.6 V Li-SOCL2, 14,250 1 x 3.7 V Li-ion battery or 230 V power adapter 4 x 1.5 V AA, operating time > 1 year (depending on sensor and configuration) 4 x 1.5V, AA, operating time > 1 year (depending on sensor and configuration) 4 x 1.5 V, AA, operating time > 1 year (depending on sensor and configuration) 4 x 1.5 V, AA, operating time > 1 year (depending on sensor and configuration) 4 x 1.5 V, AA, operating time > 1 year (depending on sensor and configuration)
External (USB)
External (LAN, PoE model)
Terminals for external power supply to supply the sensor
Dimensions
Length (packaging excluded) [mm] 94 90 166 166 166 166 166
Width (packaging excluded) [mm] 32 110 32 32 32 32 32
Height (packaging excluded) [mm] 50 98 78 78 78 78 78
Weight
(packaging excluded) [kg] 0.091 0.245 0.25 0.25 0.25 0.25 0.25
Standard scope of delivery
Standard scope of delivery
Measuring device
Battery(-ies)
Bag/holster
USB connection cable
BL30 data logger software
Lockable wall holder
Operating manual
Power adapter
PC software (download)
CD-ROM with Smartgraph PC software and operating manual
Ascertainable measured values and functions
Internal sensors
Air temperature [°C]
Air temperature [°F]
Relative humidity [%]
CO2 concentration [ppm]
Absolute humidity [g/m³]
Dew point temperature [°C]
Dew point temperature [°F]
Relative air pressure [hPa]
Absolute air pressure [hPa]
External sensors
CO2 concentration [ppm]
Unknown
Particle concentration [0.5µm]
Particle concentration [1µm]
Particle concentration [5]
Particle concentration [10]
Particle concentration [xµm]
Particle concentration [yµm]
Particle concentration [zµm]
inactive
Particle concentration [0.2µm]
Wet-bulb temperature [°C]
Wet-bulb temperature [°F]
Global radiation [W/m²]
Daylight
Amount of precipitation [l/m²]
Wind speed [m/s]
Wind direction
Ground dampness
Particle concentration [0.3µm]
Particle concentration [0.1µm]
Surface temperature [°C]
Absolute humidity [g/m³]
Surface temperature [°F]
Material temperature [°C]
Material temperature [°F]
Air temperature [°C]
Air temperature [°F]
Wood moisture [digits]
Building moisture [digits]
Relative humidity [%]
Dew point temperature [°C]
Mixing ratio [g/kgdryair]
Dew point temperature [°F]
Battery voltage [mV,V]
Voltage [mV,V]
Current [mA,A]
Absolute air pressure [hPa,Pa]
Relative air pressure [hPa,Pa]
Differential pressure [Pa]
Flow rate [m/s]
Leaf wetness
Functions and features
Minimum value display
Maximum value display
Switching function °C/°F
Alarm function
Date
Time
Freely selectable saving interval from 1 second to 24 hours
Continuous or ring recording max. 32,000 measured values (16,000 each for temperature and humidity)
Battery status indication
Measured value hold function
Automatic Baseline Calibration
Backlit display
CO2acoustic alarm function
CO2sensor
Feel-good indication

 standard equipment

 optionally available

 not available