Any questions?
We are happy to provide further information available.
Business: | +49 2452 962 400 |
---|---|
Industry: | +49 2452 962 777 |
End-consumers: | +49 2452 962 450 |
E-mail: | online-uk@trotec.com |
---|
DL200X
Universally applicable industrial data logger
The DL200X is the perfect data collector for various monitoring tasks in automation, control and feedback control systems.
Whether particle concentration, pressure, conveyor speed or flow rate, the DL200X can be configured for any requirement you may have, because instead of relying on internal sensors, it uses external connections for digital and analogue sensors.
Using an RS485 interface, up to four intelligent bus sensors can be built in, for example, particle counters or temperature-dampness sensors for cleanrooms.
Additionally, the DL200X has a 10 pin terminal, where two other analogue sensors can be attached to, for example, Pt100 temperature sensors, thermal elements (K, J, S type) or voltage and current sensors with the standardised signal for individual measurement transducer in various physical sizes and units.
At maximum configuration, six different sensors can run at the DL200X simultaneously, while universal measuring networks can operate in real time due to the device's LAN capability.
Definition of measurement channel
How many measured values can be recorded?
All devices from the DL series are powerful multi-channel data loggers with which you can not only detect, but also record all of the compatible measured values (see technical specifications).
The term "measurement channel" is not used to mean the same as it is by some of our competitors – meaning the available sensors, but instead – the same as in analysis software – it means one individually selectable "recording track", i.e. the value which should be logged.
For each measured value and measured unit (channel group), one or more of the four following types of measured values can be recorded: current, minimum, maximum or average. Each of these four values represents a measurement channel.
The maximum amount of available measurement channels for each data logger is thus the amount of detectable channel groups (e.g. temperature in °C) multiplied by the four types of measured values.
In total, 20 of these measurement channels can be freely selected for logging and three for being displayed.



All data loggers are available as an option in addition to the standard colour
anthracite, with white or yellow housing.
Practical benefits
- Maintenance-free high quality measuring device "made in Germany"
- Tamper-proof measured value detection and documentation
- Perfect for measuring over a long period
- Storage for up to 3,200,000 measured values
- Simultaneous recording of up to 20 separate measurement channels
- Network function
- Low energy consumption
- Flexible power supply via batteries or USB
- Timer function, variable measurement intervals, alarm function for each measurement channel
- Three-row LCD for measurement value display
- Including professional software
Shop

Profi-Datenlogger DL200X anthrazit
Der DL200X ist ein optimaler Datensammler für vielfältige Überwachungsaufgaben in der Automatisierungs-, Steuerungs- und Regelungstechnik.
499.80 € inkl. MwSt. Nettopreis exkl. MwSt. anzeigen
Technical data
Technical data | ||
---|---|---|
General information | ||
Article number | 3.510.260.060 | |
Air temperature [°C] | ||
Measuring principle | ||
Min. measuring range [°C] | ||
Max. measuring range [°C] | ||
Accuracy ± [°C] | ||
Display resolution [°C] | ||
Relative humidity | ||
Measuring principle | ||
Min. measuring range [% r.F.] | ||
Max. measuring range [% r.F.] | ||
Accuracy [% r.F.] | ||
Display resolution [% r.f.] | ||
Air pressure | ||
measuring principle | ||
Measuring range [hPa] | ||
Accuracy ± [hPa] | ||
Display resolution [hPa] | ||
CO2 concentration | ||
Measuring principle | ||
Measuring range [ppm] | ||
Display resolution [ppm] | ||
Accuracy | ||
Long-term stability [ppm/a] | ||
Thermal element K | ||
Min. measuring range [°C] | -200 | |
Max. measuring range [°C] | 1,200 | |
Accuracy Between -200 °C ... 0 °C [°C] | ±1 | |
Accuracy Between -200 °C ... 0 °C [°C] - Of measured value | ±0.5 | |
Accuracy Between 0 °C ... 1.200 °C [°C] | ±0 | |
Accuracy Accuracy between 0 °C ... 1.200 °C [°C] - Of measured value | ±0.2 | |
Resolution [°C] | 0.2 | |
Thermal element J | ||
Min. measuring range [°C] | -200 | |
Max. measuring range [°C] | 1,200 | |
Accuracy -200 °C ... 0 °C [°C] | ±1 | |
Accuracy -200 °C ... 0 °C [°C] - Of measured value | ±0.5 | |
Accuracy Accuracy between 0 °C ... 1.200 °C [°C] | ±1 | |
Accuracy Accuracy between 0 °C ... 1.200 °C [°C] - Of measured value | ±0.2 | |
Resolution [°C] | 0.2 | |
Thermal element S | ||
Min. measuring range [°C] | -50 | |
Max. measuring range [°C] | 1,700 | |
Accuracy Between -50 °C ... 0 °C [°C] | ±1 | |
Accuracy Between -50 °C ... 0 °C [°C] - Of measured value | 0.5 | |
Accuracy 0 °C ... 1.700 °C [°C] | ±1 | |
Accuracy 0 °C ... 1.700 °C [°C] - Of measured value | ±0.2 | |
Resolution [°C] | 0.2 | |
PT100 | ||
Min measuring range [°C] | -200 | |
Max. measuring range [°C] | 500 | |
Accuracy [°C] | 0.2 | |
Accuracy of the measured value ± [%] | 1 | |
Resolution [°C] | 0.02 | |
Voltage input | ||
Min. measuring range [V] | 0 | |
Max. measuring range [V] | 1 | |
Accuracy ± [µV] | 200 | |
Accuracy of the measured value - Voltage input ± [%] | 1 | |
Resolution | < 500 | |
Current measurement | ||
Min. measuring range in two-wire operation [mA] | 4 | |
Max. measuring range in two-wire operation [mA] | 20 | |
Min. measuring range in three-wire operation [mA] | 0 | |
Max. measuring range in three-wire operation [mA] | 20 | |
Accuracy ± [µA] | 4 | |
Accuracy of the measured value ± [%] | 0.1 | |
Resolution [µA] | 5 | |
Approx. output load [Ω] | 50 | |
Display | ||
LCD | ||
Size [mm] | 90 x 64 | |
Memory organisation | ||
Sampling interval | 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h | |
Saving interval | 1/10/12/15/30 min, 1/3/6/12/24 h | |
Memory | 16 MB, 3,200,000 measured values | |
Data logging | Up to 20 measurement channels in parallel | |
Available measurement channels | Max. 128 | |
Available channel groups | Max. 32 | |
Software | TR, EN, EN, ES, FR | |
Interface | ||
LAN | ||
RS-485 | ||
10-pin terminal | ||
USB | ||
BNC | ||
Plug socket | ||
Housing design | ||
Plastics | ||
Power supply | ||
Internal (battery) | 4 x 1.5 V, AA, operating time > 1 year (depending on sensor and configuration) | |
External (USB) | ||
External (LAN, PoE model) | ||
Terminals for external power supply to supply the sensor | ||
Dimensions | ||
Length (packaging excluded) [mm] | 166 | |
Width (packaging excluded) [mm] | 32 | |
Height (packaging excluded) [mm] | 78 | |
Weight | ||
(packaging excluded) [kg] | 0.25 |
Standard scope of delivery | ||
---|---|---|
Standard scope of delivery | ||
Measuring device | ||
Battery(-ies) | ||
USB connection cable | ||
CD-ROM with Smartgraph PC software and operating manual |
Ascertainable measured values and functions | ||
---|---|---|
Internal sensors | ||
Air temperature [°C] | ||
Air temperature [°F] | ||
Relative humidity [%] | ||
Absolute humidity [g/m³] | ||
Dew point temperature [°C] | ||
Dew point temperature [°F] | ||
Relative air pressure [hPa] | ||
Absolute air pressure [hPa] | ||
CO2 concentration [ppm] | ||
External sensors | ||
CO2 concentration [ppm] | ||
Surface temperature [°C] | ||
Surface temperature [°F] | ||
Material temperature [°C] | ||
Material temperature [°F] | ||
Air temperature [°C] | ||
Air temperature [°F] | ||
Wood moisture [digits] | ||
Building moisture [digits] | ||
Relative humidity [%] | ||
Absolute humidity [g/m³] | ||
Dew point temperature [°C] | ||
Dew point temperature [°F] | ||
Battery voltage [mV, V] | ||
Voltage [mV, V] | ||
Current [mA, A] | ||
Absolute air pressure [hPa, Pa] | ||
Relative air pressure [hPa, Pa] | ||
Differential pressure [Pa] | ||
Flow rate [m/s] | ||
Mixing ratio [g/kg dry air] | ||
Particle concentration [0.1 µm] | ||
Particle concentration [0.2 µm] | ||
Particle concentration [0.3 µm] | ||
Particle concentration [0.5 µm] | ||
Particle concentration [1 µm] | ||
Particle concentration [5] | ||
Particle concentration [10] | ||
Particle concentration [x µm] | ||
Particle concentration [y µm] | ||
Particle concentration [z µm] | ||
Unknown | ||
inactive | ||
Wet-bulb temperature [°C] | ||
Wet-bulb temperature [°F] | ||
Global radiation [W/m²] | ||
Daylight | ||
Amount of precipitation [l/m²] | ||
Wind speed [m/s] | ||
Wind direction | ||
Ground dampness | ||