1. Products & Services
  2. Products ‑ HighPerformance
  3. Heating
  4. Multi air handler TAC XT
  5. Hub TAC XT

TAC XT – one device, two power versions, four key applications

HEPA air purification and virus filtration with the TAC XT

HEPA air purification and virus filtration

An optional H14 HEPA filter can be used singly for room air purification or as an effective virus filter system for on-demand thermal decontamination as well as in combined heating operation for synchronous room heating and air purification.

Find out more …

High-performance heating of interior spaces with the TAC XT
Heating and air purification with the TAC XT

High-performance interior heating

With 18 or 27 kW heating power, the TAC XT provides draught-free warm air throughout the room with a working radius of 360° and can also be used to connect a fabric air distributor or air distribution systems. Simultaneous HEPA air purification is also possible.

Find out more …

Thermal room and surface decontamination with the TAC XT

Thermal decontamination

With the TAC XT, COVID-19 and other viruses won't have any chance: its serial programming also allows it to be used as a mobile thermal disinfector for flexible and efficient inactivation of microorganisms both in the room air and on surfaces.

Find out more …

TAC XT – one device, two power versions, four key applications

HEPA air purification and virus filtration with the TAC XT

HEPA air purification and virus filtration

An optional H14 HEPA filter can be used singly for room air purification or as an effective virus filter system for on-demand thermal decontamination as well as in combined heating operation for synchronous room heating and air purification.

Find out more …

High-performance heating of interior spaces with the TAC XT
Heating and air purification with the TAC XT

High-performance interior heating

With 18 or 27 kW heating power, the TAC XT provides draught-free warm air throughout the room with a working radius of 360° and can also be used to connect a fabric air distributor or air distribution systems. Simultaneous HEPA air purification is also possible.

Find out more …

Thermal disinfestation with the TAC XT

Thermal disinfestation

A special hot air disinfestation treatment programme ensures the killing of any kind of vermin within the treatment radius – efficient and 100 % environmentally friendly, without chemicals or insecticides!

Find out more …

Thermal room and surface decontamination with the TAC XT

Thermal decontamination

With the TAC XT, COVID-19 and other viruses won't have any chance: its serial programming also allows it to be used as a mobile thermal disinfector for flexible and efficient inactivation of microorganisms both in the room air and on surfaces.

Find out more …

Possible applications and equipment differences of TAC high-performance air purifiers at a glance

Trotec high-performance air purifiers with HEPA H14 suitability in compliance with EN 1822 (corresponds to ISO 45 H according to ISO 29463) TAC XT TAC V+ TAC M TAC ECO TAC BASIC
TAC XT TAC V+ TAC M TAC ECO TAC BASIC
Use for high-performance H14 HEPA air purification as per EN 1822
Integral silencer
Stationary stand version
Mobile carriage design
Usage-related filter change indicator for prefilter and HEPA filter
FlowMatic volumetric flow control
Programmable touch display updateable via USB
Thermal filter decontamination and filter regeneration
Use for room heating, tent heating (heating capacity 18/27 kW)
Use for thermal decontamination of rooms and objects
Use for thermal disinfestation
Trotec high-performance air purifiers with HEPA H14 suitability in compliance with EN 1822 (corresponds to ISO 45 H according to ISO 29463) TAC XT TAC V+ TAC M TAC ECO TAC BASIC
Use for high-performance H14 HEPA air purification as per EN 1822
Integral silencer
Stationary stand version
Mobile carriage design
Usage-related filter change indicator for prefilter and HEPA filter
FlowMatic volumetric flow control
Programmable touch display updateable via USB
Thermal filter decontamination and filter regeneration
Use for room heating, tent heating (heating capacity 18/27 kW)
Use for thermal decontamination of rooms and objects
Use for thermal disinfestation
TAC high-performance air purifiers – show more technical data
TAC high-performance air purifiers – more technical data at a glance TAC XT TAC V+ TAC M TAC ECO TAC BASIC
TAC XT TAC V+ TAC M TAC ECO TAC BASIC
Max. air flow rate heating (without HEPA filter) 2,500 m³/h - - - -
Max. air volume flow for the respective filter class with standard HighFlow H14 HEPA Heat Resistant filter:
H14 ≤ 1,200 m³/h, H13 ≤ 2,100 m³/h
H14 ≤ 1,000 m³/h
H13 ≤ 1,600 m³/h
Prefilter F7 (EN 779:2002), ePM10 85 % (ISO 16890) G4 Z-line
(EN 779:2002)
High-temperature particulate air filter TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822
Fully encapsulated H14 HighFlow metal lamellae high-temperature filter “made in Germany”

Each filter is tested and certified individually.
TROTEC HEPA H14, EN 1822
(standard minipleat)
Each filter is tested and certified individually.
Filter change interval approx. 2 to 4 years
(depending on the application and with regular thermal decontamination)
approx. 1 to 3 years
(depending on the application)
approx. 1 to 2 years
(depending on the application)
max. 1 to 2 years
Filter change indication Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter -
FlowMatic control Constant clean air volume flow,
constant circulation rates in each power level

also with increasing filter contamination. Air volume freely adjustable in m³.
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
Time freely programmable,
the thermal decontamination and filter regeneration process takes place fully automatically, usually once a week at night or outside business or teaching hours.
Thermal decontamination and filter regeneration can be switched off temporarily or even constantly as required.

Due to the short treatment duration (15 min.) and the low energy input (altogether approx. 1.0 kWh per cycle), the room temperature does not increase by thermal decontamination.
No thermal decontamination and
reconditioning of the filter
Mains connection (connector plug) 380–480 V 50 / 60 Hz (CEE 32 A) 220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F)
ø power consumption Air purification: 0.15 kW*, 1.25 kW (short-term peak load, e.g. once a week during thermal decontamination)
heating: max. 27 kW
0.15 kW*,
1.25 kW (short-term peak load, e.g. once a week during thermal decontamination)
0.15 kW*
Exemplary total energy consumption
(with 900 m³/h air volume)
Without thermal decontamination approx. 1.2 kWh per day / approx. 24 kWh per month*

With thermal decontamination approx. 1.4 kWh per day / approx. 28 kWh per month
* and thermal decontamination once a week
approx. 1.2 kWh per day /
approx. 24 kWh per month*
Control panel Programmable, USB updateable touch display with PIN-protected lock function Manual control panel
(6-step switch)
Dimensions L x W x H
With wheels and handle
(mobile housing)

690 mm x 630 mm x 1,300 mm to 2,300 mm **

Width with optional sound protection caps: 770 mm

690 mm x 630 mm x 1,130 mm to 2,300 mm **

Width with optional sound protection caps: 770 mm
Dimensions L x W x H
(stationary housing)

506 x 523 x 1,100 mm to 2,300 mm **

Width with optional sound protection caps: 770 mm
Weight
(mobile housing)

TAC XT 18:
104 kg (incl. filter)

TAC XT 27:
109 kg (incl. filter)

89 kg (incl. filter) 86 kg (incl. filter) 83 kg (incl. filter)
Weight
(stationary housing)
85 kg (incl. filter) 81 kg (incl. filter) 78 kg (incl. filter) 73 kg (incl. filter)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
TAC XT
Max. air flow rate heating (without HEPA filter)
2,500 m³/h
Max. air volume flow for the respective filter class
with standard HighFlow H14 HEPA Heat Resistant filter:
H14 ≤ 1,200 m³/h, H13 ≤ 2,100 m³/h
Prefilter
F7 (EN 779:2002), ePM10 85 % (ISO 16890)
High-temperature particulate air filter
TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822
Fully encapsulated H14 HighFlow metal lamellae high-temperature filter “made in Germany”
(optional also as Ultra-HighFlow filter).
Each filter is tested and certified individually.
Filter change interval
Approx. 2 to 4 years
(depending on the application and with regular thermal decontamination)
Filter change indication
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter
FlowMatic control
Constant clean air volume flow,
constant circulation rates in each power level

also with increasing filter contamination. Air volume freely adjustable in m³.
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
Time freely programmable,
the thermal decontamination and filter regeneration process takes place fully automatically, usually once a week at night or outside business or teaching hours.
Thermal decontamination and filter regeneration can be switched off temporarily or even constantly as required.

Due to the short treatment duration (15 min.) and the low energy input (altogether approx. 1.0 kWh per cycle), the room temperature does not increase by thermal decontamination.
Mains connection (connector plug)
380–480 V 50 / 60 Hz (CEE 32 A)
ø power consumption
Air purification: 0.15 kW*, 1.25 kW (short-term peak load, e.g. once a week during thermal decontamination)
heating: max. 27 kW
Exemplary total energy consumption
(with 900 m³/h air volume)
Without thermal decontamination approx. 1.2 kWh per day / approx. 24 kWh per month*

With thermal decontamination approx. 1.4 kWh per day / approx. 28 kWh per month
* and thermal decontamination once a week
Control panel
Programmable, USB updateable touch display with PIN-protected lock function
Dimensions L x W x H (mobile housing)
With wheels and handle:
690 mm x 630 mm x 1,300 mm to 2,300 mm **
Width with optional sound protection caps: 770 mm
Dimensions L x W x H (stationary housing)
Weight (mobile housing)
TAC XT 18: 104 kg (incl. Filter)
TAC XT 27: 109 kg (incl. Filter)
Weight (stationary housing)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
TAC V+
Max. air flow rate heating (without HEPA filter)
-
Max. air volume flow for the respective filter class
with standard HighFlow H14 HEPA Heat Resistant filter:
H14 ≤ 1,200 m³/h, H13 ≤ 2,100 m³/h
Prefilter
F7 (EN 779:2002), ePM10 85 % (ISO 16890)
High-temperature particulate air filter
TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822
Fully encapsulated H14 HighFlow metal lamellae high-temperature filter “made in Germany”
(optional also as Ultra-HighFlow filter).
Each filter is tested and certified individually.
Filter change interval
Approx. 2 to 4 years
(depending on the application and with regular thermal decontamination)
Filter change indication
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter
FlowMatic control
Constant clean air volume flow,
constant circulation rates in each power level

also with increasing filter contamination. Air volume freely adjustable in m³.
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
Time freely programmable,
the thermal decontamination and filter regeneration process takes place fully automatically, usually once a week at night or outside business or teaching hours.
Thermal decontamination and filter regeneration can be switched off temporarily or even constantly as required.

Due to the short treatment duration (15 min.) and the low energy input (altogether approx. 1.0 kWh per cycle), the room temperature does not increase by thermal decontamination.
Mains connection (connector plug)
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F)
ø power consumption
0.15 kW*,
1.25 kW (short-term peak load, e.g. once a week during thermal decontamination)
Exemplary total energy consumption
(with 900 m³/h air volume)
Without thermal decontamination approx. 1.2 kWh per day / approx. 24 kWh per month*

With thermal decontamination approx. 1.4 kWh per day / approx. 28 kWh per month
* and thermal decontamination once a week
Control panel
Programmable, USB updateable touch display with PIN-protected lock function
Dimensions L x W x H (mobile housing)
With wheels and handle:
690 x 630 x 1,300 mm to 2,300 mm **
Width with optional sound protection caps: 770 mm
Dimensions L x W x H (stationary housing)
506 x 523 x 1,100 mm to 2,300 mm **
Width with optional sound protection caps: 770 mm
Weight (mobile housing)
89 kg (incl. Filter)
Weight (stationary housing)
85 kg (incl. Filter)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
TAC M
Max. air flow rate heating (without HEPA filter)
-
Max. air volume flow for the respective filter class
with standard HighFlow H14 HEPA Heat Resistant filter:
H14 ≤ 1,200 m³/h, H13 ≤ 2,100 m³/h
Prefilter
F7 (EN 779:2002), ePM10 85 % (ISO 16890)
High-temperature particulate air filter
TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822
Fully encapsulated H14 HighFlow metal lamellae high-temperature filter “made in Germany”
(optional also as Ultra-HighFlow filter).
Each filter is tested and certified individually.
Filter change interval
Approx. 1 to 3 years (depending on the application)
Filter change indication
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter
FlowMatic control
Constant clean air volume flow,
constant circulation rates in each power level

also with increasing filter contamination. Air volume freely adjustable in m³.
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
No thermal decontamination and
reconditioning of the filter
Mains connection (connector plug)
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F)
ø power consumption
0.15 kW*
Exemplary total energy consumption
(with 900 m³/h air volume)
approx. 1.2 kWh per day /
approx. 24 kWh per month*
Control panel
Programmable, USB updateable touch display with PIN-protected lock function
Dimensions L x W x H (mobile housing)
With wheels and handle:
690 x 630 x 1,300 mm to 2,300 mm **
Width with optional sound protection caps: 770 mm
Dimensions L x W x H (stationary housing)
506 x 523 x 1,100 mm to 2,100 mm **
Width with optional sound protection caps: 770 mm
Weight (mobile housing)
86 kg (incl. Filter)
Weight (stationary housing)
81 kg (incl. Filter)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
TAC ECO
Max. air flow rate heating (without HEPA filter)
-
Max. air volume flow for the respective filter class
H14 ≤ 1,000 m³/h
H13 ≤ 1,600 m³/h
Prefilter
G4 Z-line (EN 779:2002)
High-temperature particulate air filter
TROTEC HEPA H14, EN 1822
(standard minipleat)
Each filter is tested and certified individually.
Filter change interval
Approx. 1 to 2 years(depending on the application)
Filter change indication
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter
FlowMatic control
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
No thermal decontamination and
reconditioning of the filter
Mains connection (connector plug)
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F)
ø power consumption
0.15 kW*
Exemplary total energy consumption
(with 900 m³/h air volume)
approx. 1.2 kWh per day /
approx. 24 kWh per month*
Control panel
Manual control panel (6-step switch)
Dimensions L x W x H (mobile housing)
With wheels and handle:
690 x 630 x 1,130 mm to 2,300 mm **
Width with optional sound protection caps: 770 mm
Dimensions L x W x H (stationary housing)
506 x 523 x 1,100 mm to 2,100 mm **
Width with optional sound protection caps: 770 mm
Weight (mobile housing)
83 kg (incl. Filter)
Weight (stationary housing)
78 kg (incl. Filter)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
TAC BASIC
Max. air flow rate heating (without HEPA filter)
-
Max. air volume flow for the respective filter class
H14 ≤ 1,000 m³/h
H13 ≤ 1,600 m³/h
Prefilter
G4 Z-line (EN 779:2002)
High-temperature particulate air filter
TROTEC HEPA H14, EN 1822
(standard minipleat)
Each filter is tested and certified individually.
Filter change interval
Max. 1 to 2 years
Filter change indication
FlowMatic control
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
No thermal decontamination and
reconditioning of the filter
Mains connection (connector plug)
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F)
ø power consumption
0.15 kW*
Exemplary total energy consumption
(with 900 m³/h air volume)
approx. 1.2 kWh per day /
approx. 24 kWh per month*
Control panel
Manual control panel (6-step switch)
Dimensions L x W x H (mobile housing)
Dimensions L x W x H (stationary housing)
506 x 523 x 1,100 mm to 2,100 mm **
Width with optional sound protection caps: 770 mm
Weight (mobile housing)
Weight (stationary housing)
73 kg (incl. filter)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
Available colour variants
TAC XT
Available colour versions
Yellow
Also available as stainless steel version
TAC V+
Available colour versions
Yellow, basalt grey, white, bronze
Also available as stainless steel version
TAC M
Available colour versions
Yellow, basalt grey, white, bronze
Also available as stainless steel version
TAC ECO
Available colour versions
Basalt grey
Also available as stainless steel version
TAC BASIC
Available colour versions
Basalt grey
Also available as stainless steel version