Alle einblenden x BL30 x BZ30 x DL200D x DL200H x DL200L x DL200P x DL200X
BL30
BZ30
DL200D
DL200H
DL200L
DL200P
DL200X

Technical data Standard scope of delivery Ascertainable measured...

Sie sparen: 31 %

79.94 € 54.95 € inkl. MwSt.
Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

179.94 € inkl. MwSt.
Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

449.82 € inkl. MwSt.
Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

299.88 € inkl. MwSt.
Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

499.80 € inkl. MwSt.
Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

399.84 € inkl. MwSt.
Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

499.80 € inkl. MwSt.
Nettopreis exkl. MwSt. anzeigen

jetzt kaufen

Technical data
General information
Article number 3.510.205.520 3.510.205.015 3.510.260.040 3.510.260.020 3.510.260.050 3.510.260.030 3.510.260.060
Air temperature [°C]
Display resolution [°C] 0.1 0.1 0.1 0.1 0.1 0.1
Accuracy ± [°C] 2 1 0.3 0.3
Max. measuring range [°C] 70 50 50 50 50 50
Measuring principle NTC NTC NTC NTC NTC NTC
Min. measuring range [°C] -40 -5 -20 -20 -20 -20
Accuracy ± 0 °C - 40 °C [°C] 0.3
Air temperature [°F]
Accuracy ± [°F] 1.8 1.8
Display resolution [°F] 0.1 0.1
Max. measuring range [°F] 158 122
Min. measuring range [°F] -40 23
Relative humidity
Measuring principle Capacitive Capacitive Capacitive Capacitive
Anzeigeauflösung [% r.F.] 0.5 0.1 0.5 0.5
Accuracy [% RH] 5
Anzeigeauflösung [% RH] 0.1 0.1
Max. measuring range [% RH] 100 99.9 100 100 100 100
Accuracy ± [% RH] 3.5 2 2 2 2
Min. measuring range [% RH] 0 0.1 10 10 10 10
Air pressure
Display resolution [hPa] 0.1
Accuracy ± [hPa] 0.5
Measuring range [hPa] 300 - 1,300 (absolute air pressure)
measuring principle
CO₂ concentration
Display resolution [ppm] 1 1
Measuring range [ppm] 0 - 5,000
Long-term stability [ppm/a] 20
Accuracy ±75 ppm / ±5 % ± 50 ppm / + 3% of measured value (at 20°C and 1,013 mbar)
Accuracy [%] 5
Min. measuring range [ppm] 0
Max. measuring range [ppm] 9,999
Accuracy [ppm] 75
Measuring principle NDIR NDIR
Thermal element K
Min. measuring range [°C] -200
Resolution [°C] 0.2
Max. measuring range [°C] 1,200
Accuracy Accuracy between 0 °C ... 1,200 °C [°C] - Of measured value ±0.2
Accuracy Between -200 °C ... 0 °C [°C] - Of measured value ±0.5
Accuracy Between -200 °C ... 0 °C [°C] ±1
Accuracy Between 0 °C ... 1,200 °C [°C] ±0
Thermal element J
Accuracy Accuracy between 0 °C ... 1,200 °C [°C] - Of measured value ±0.2
Resolution [°C] 0.2
Accuracy Accuracy between 0 °C ... 1,200 °C [°C] ±1
Accuracy -200 °C ... 0 °C [°C] - Of measured value ±0.5
Max. measuring range [°C] 1,200
Accuracy -200 °C ... 0 °C [°C] ±1
Min. measuring range [°C] -200
Thermal element S
Accuracy 0 °C ... 1,700 °C [°C] - Of measured value ±0.2
Resolution [°C] 0.2
Accuracy 0 °C ... 1,700 °C [°C] ±1
Accuracy Between -50 °C ... 0 °C [°C] - Of measured value 0.5
Max. measuring range [°C] 1,700
Accuracy Between -50 °C ... 0 °C [°C] ±1
Min. measuring range [°C] -50
PT100
Resolution [°C] 0.02
Accuracy of the measured value ± [%] 1
Accuracy [°C] 0.2
Max. measuring range [°C] 500
Min measuring range [°C] -200
Voltage input
Resolution < 500
Accuracy of the measured value - Voltage input ± [%] 1
Accuracy ± [µV] 200
Max. measuring range [V] 1
Min. measuring range [V] 0
Current measurement
Accuracy of the measured value ± [%] 0.1
Resolution [µA] 5
Approx. output load [Ω] 50
Accuracy ± [µA] 4
Max. measuring range in three-wire operation [mA] 20
Max. measuring range in two-wire operation [mA] 20
Min. measuring range in three-wire operation [mA] 0
Min. measuring range in two-wire operation [mA] 4
Display
Size [mm] 90 x 64 90 x 64 90 x 64 90 x 64 90 x 64
Monochrome
LCD
Memory organisation
Available channel groups 8 6 7 Max. 12 Max. 32
Software TR, DE, EN, ES, FR TR, DE, EN, ES, FR TR, DE, EN, ES, FR TR, DE, EN, ES TR, DE, EN, ES, FR
Available measurement channels 32 24 28 Max. 48 Max. 128
Data logging Up to 20 measurement channels in parallel Up to 20 measurement channels in parallel Up to 20 measurement channels in parallel Up to 20 measurement channels in parallel Up to 20 measurement channels in parallel
Saving interval as of 1 s > 1 s 1/10/12/15/30, 1/3/6/12/24 h 1/10/12/15/30 min, 1/3/6/12/24 h 1/10/12/15/30 min 1/10/12/15/30 min, 1/3/6/12/24 h 1/10/12/15/30 min, 1/3/6/12/24 h
Memory 32,000 Measured values, (16,000 each for temperature and humidity) 50,000 Measured values 16 MB, 3,200,000 measured values 16 MB, 3,200,000 measured values 16 MB, 3,200,000 measured values 16 MB, 3,200,000 measured values 16 MB, 3,200,000 measured values
Sensing interval as of 1 s > 1 s 10/30s, 1/10/12/15/30 min, 1/3/6/12/24h 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h
Interface
10-pin terminal
Plug socket - 2x
BNC - 2x
RS-485
BNC
LAN
Plug socket
USB
[Interface
USB
Device control
Push buttons
Housing design
Plastic
Power supply
Terminals for external power supply to supply the sensor
External (LAN, PoE model)
External (USB)
Internal (battery) 1 x 3.6 V Li-SOCL2, 14,250 1x 3.7 V, Li-Ion battery or 230 V power adapter 4 x 1.5 V AA, operating time > 1 year (depending on sensor and configuration) 4 x 1.5V, AA, operating time > 1 year (depending on sensor and configuration) 4 x 1.5 V, AA, operating time > 1 year (depending on sensor and configuration) 4 x 1.5 V, AA, operating time > 1 year (depending on sensor and configuration) 4 x 1.5 V, AA, operating time > 1 year (depending on sensor and configuration)
Dimensions
Length (packaging excluded) [mm] 94 110 166 166 166 166 166
Width (packaging excluded) [mm] 32 61 32 32 32 32 32
Height (packaging excluded) [mm] 50 105 78 78 78 78 78
Weight
(packaging excluded) [kg] 0.091 0.074 0.25 0.25 0.25 0.25 0.25
Standard scope of delivery
Standard scope of delivery
Operating manual
Power adapter
CD-ROM with Smartgraph PC software
CD-ROM with Smartgraph PC software and operating manual
Lockable wall holder
BL30-Datalogger-Software
Battery(-ies)
Bag/Holster
USB connection cable
Measuring device
Ascertainable measured values and functions
Internal sensors
Dew point temperature [°F]
Relative air pressure [hPa]
Absolute air pressure [hPa]
Dew point temperature [°C]
Absolute humidity [g/m³]
Air temperature [°F]
Relative humidity [%]
CO₂ concentration [ppm]
Air temperature [°C]
External sensors
Particle concentration [10]
Particle concentration [x µm]
Particle concentration [y µm]
Particle concentration [z µm]
Particle concentration [5]
Particle concentration [1 µm]
Particle concentration [0.2 µm]
Particle concentration [0.3 µm]
Particle concentration [0.5 µm]
Unknown
Inactive
Wind speed [m/s]
Wind direction
Ground dampness
Leaf wetness
Amount of precipitation [l/m²]
Daylight
Wet-bulb temperature [°C]
Wet-bulb temperature [°F]
Global radiation [W/m²]
Particle concentration [0.1 µm]
Mixing ratio [g/kg dry air]
Air temperature [°F]
Wood moisture [digits]
Building moisture [digits]
Relative humidity [%]
Air temperature [°C]
Material temperature [°F]
Surface temperature [°C]
Surface temperature [°F]
Material temperature [°C]
Absolute humidity [g/m³]
Dew point temperature [°C]
Relative air pressure [hPa, Pa]
Differential pressure [Pa]
Flow rate [m/s]
Absolute air pressure [hPa, Pa]
Current [mA, A]
Dew point temperature [°F]
Battery voltage [mV, V]
Voltage [mV, V]
CO₂ concentration [ppm]
Functions and features
Backlit display
Hold function
CO2acoustic alarm function
CO2sensor
Feel-good indication
Continuous or ring recording max. 32,000 measured values (16,000 each for temperature and humidity)
Freely selectable saving interval from 1 second to 24 hours
Switching function °C/°F
Maximum value display
Alarm function
Date
Time
Minimum value display

 Serienausstattung

 optional erhältlich

 nicht verfügbar